The MDE NPRM proposed that where there is a change in level at the entry of a wheelchair space that is greater than 1½ inches, the entry shall be ramped and have a running slope not steeper...
Search Results "Adult Changing Table"
-
3. Exception to Ramp Running Slope
- Defining and Delivering Disability-Competent Care - The Lived Experience Of Disability
-
M302.2.1 Adjustability (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability) in the final rule the Access Board has renamed this provision and now requires the transfer surface to be adjustable to: (1) a low...
-
T402.9 Transitions
Vertical surface discontinuities at transitions from boarding and alighting areas to ramps and bridgeplates shall comply with T302.4.
-
M305.2.5 Surface Hazards
Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges.
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports. No public comments were submitted on this issue, but the MDE...
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2 Description: This provision prescribes a cross-sectional profile of the transfer...
-
5.4 Transfer Supports
5.4 Transfer Supports.
-
5.4 Transfer Supports Recommendations
5.4 Transfer Supports Recommendations
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
9.5.2(2)(e)
(c) and (d) which a person with mobility impairments can use including minimum clear width of 36 in (915 mm), passing space complying with 4.3.4, turning space complying with 4.2.3 and changes...
-
11B-503.4 Floor and ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
4.1.6 Surface
The surface of the clear floor or ground space shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
Surface and Size [§305.2 and §305.3]
They must be free of level changes and not slope more than 1:48. The minimum size (30” by 48”) applies whether the space is positioned for forward or side approaches....
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position. A 3-inch maximum obstruction is permitted at transfer...
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be positioned 6 inches minimum and 19 inches maximum...
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer...
-
202.4 Alterations Affecting Primary Function Areas
constructed or altered in accordance with the April 1, 1994 Texas Accessibility Standards (TAS) they will enjoy safe harbor and are not required to be retrofitted to reflect the incremental changes...