is upgraded or replaced, or a new fire alarm system is installed....
Search Results "Transit System"
-
Visible Alarms in Alterations to Existing Facilities
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3....
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.4 _|Visible alarms;...
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3 _|Visible alarms;...
-
6. Recognize that Proper Installation of Play Surface Systems is Key
Recognize that Proper Installation of Play Surface Systems is Key An accessible surface system can be rendered useless if it is not properly installed....
-
Signs must be provided to notify spectators of the availability of receivers
• Signs must be provided to notify spectators of the availability of receivers for the assistive listening system....
-
DEPARTMENT OF TRANSPORTATION DISABILITY LAW GUIDANCE: Paratransit Requirements for §5311-Funded Fixed-Route Service Operated by Private Entities
is obviously an arrangement or relationship between the state and XYZ Nonprofit Transit Service. ...
- Alertus Alert Beacons®
-
11B-708.4.1 Common use or public use system interface
11B-708.4.1 Common use or public use system interface....
- The Wayfindr Open Standard
-
§ 37.51 Key stations in commuter rail systems
[56 FR 45621, Sept. 6, 1991, as amended at 58 FR 63102, Nov. 30, 1993; 79 FR 21405, Apr. 16, 2014]
-
Typical Day - Public Entities: (State and Local Governmental Entities)
Self-Evaluations and Transition Plans (3 - 5 hours) Perhaps the least understood of all requirements of the ADA is the responsibility of all state and local governmental entities to prepare...
-
14. Payment
A passenger's request for a fixed route or paratransit driver to provide the transit service when the passenger with a disability cannot or refuses to pay the fare may be denied....
-
1009.2.1 Elevators required
In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with...
-
1009.2.1 Elevators required
Exceptions: In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1 or 903.3.1.2, the elevator shall not be required on floors...
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
1007.2.1 Elevators required
In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with...
-
§27.71(d)
(d) Systems of inter-terminal transportation, including, but not limited to, shuttle vehicles and people movers, shall comply with applicable requirements of the Department of Transportation's...
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
T704.2.2 Operation
Operable parts on stop request systems shall comply with T304....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....