A level landing 4 feet (1219 mm) deep shall be provided at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or...
Search Results "Slope"
-
1127B.5, Item 4
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
10 - foot straightedge method
The same problem exists when measuring slope. There is no way to measure a localized slope that may actually be greater than the overall slope of the straightedge....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
RAMP
A walking surface in an accessible space that has a running slope greater than 1:20....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
GRADE BREAK
[DSA-AC] The line where two surface planes with different slopes meet....
-
TRANSITION PLATE
[DSA-AC] A sloping pedestrian walking surface located at the end(s) of a gangway....
-
9.a [§ 4.7.5]
To answer this question you need to determine the slope of the flared sides to make sure it is 10 percent or less....
-
405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
Roll-in Access [1014.2.2]
To provide roll-in access into a camp shelter, a level or sloped entry route that complies with the technical requirements for an ORAR or trail, as applicable, must be provided along the...
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this chapter....
-
11B-233.3.1.2.6.2 Test number one, individual building test
The slopes of the undisturbed site measured in a straight line between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15,240 mm) of the planned entrance...
-
Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
106.5.13 Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
c-i
If Yes, is a ramp or sloped hallway provided? Yes No If Yes, go to question E1-d....
-
11B-411.2.1.3.4 Position
SECTION TITLE NOTES 11B-411.2.1.3.4 Position Clarifies requirements for sloping of screen and...
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
Handrail Extensions
ADAAG does not require handrails on sloped surfaces that have a rise of less than 6 inches or a projection less than 72 inches, or a slope of 1:20 (5%) or less....
-
Accessible Routes Adjacent to the Playing Surface
The accessible route provisions in ADAAG address slope (maximum of 1:12 or 8.33%), width (minimum of 36 inches), cross slope (maximum of 1:50 or 2%), handrails, and changes in level....
-
405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....