A Collapsible Shower Dam keeps water in the shower and off the bathroom floor. Sometimes called a Collapsible Water Retainer, it collapses when a wheelchair rolls over it....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
- Collapsible Water Retainer Shower Dam for Shower Threshold Information Video
-
Specifications for Alternate Roll-in Shower Controls
Specifications for controls, faucets, and shower spray units for alternate roll-in showers are provided in section 608.5.3....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
608.3.3 Alternate Roll-In Type Shower Compartments
608.3.3 Alternate Roll-In Type Shower Compartments....
-
3.4.6 Surface
The surface of each viewing area shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
Wheelchair Spaces
Wheelchair Spaces Maneuvering into wheelchair spaces is often easier from the front or back than from the side, especially where they are paired....
- Bobrick Accessibility Video -- Design for Turning Radiuses
-
2. Roll-in Shower Size
If there are more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who use wheelchairs...
-
GROUND FLOOR
[DSA-AC] The floor of a building with a building entrance on an accessible route. A building may have one or more ground floors....
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
- Figure 1009.4.3 Depth and Length of Tranfer Walls – Drawing from the U.S. Access Board
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
- McGuire Manufacturing Co., Inc. 155CRSWC: Offset Lavatory Strainer with Chain and Rubber Stopper
-
Clear Tread Width and Passing Spaces for Outdoor Recreation Access Routes
Where the clear tread width of a route is less than 60 inches (1,525 millimeters), passing spaces are required at least every 200 feet (61 meters)....