The bench shall be mounted 17 in to 19 in (430 mm to 485 mm) above the finish floor....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
4.35.4 Bench
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
4.21.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
4.21.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
11B-604.3.2 Overlap
floor space and clearances required at other fixtures, and the turning space....
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
11B-608.1 General
Shower compartments shall comply with Section 11B-608. Advisory 11B-608.1 General....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
Grab Bars: ADA Standard Section 608.3
Section 608.3 covers the current ADA Standards for grab bars in shower compartments.
- Access Board: Clear Floor Space Position
- Landscape Forms Inc. Sort Recycling Units
-
9.5.2(2)(c)
(c) at least one toilet room for each gender or one unisex toilet room shall have a minimum clear door width of 32 in (815 mm), minimum turning space complying with 4.2.3, one water closet...
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-604.3.2 Overlap
floor space and clearances required at other fixtures, and the turning space....
-
11B-604.3.2 Overlap
floor space and clearances required at other fixtures, and the turning space....
-
Rectangular Seats: ADA Standard Section 610.3.1
Section 610.3.1 covers the current ADA Standards for rectangular shower compartment seats.
-
Circular Space: ADA Standard Section 304.3.1
Section 304.3.1 covers the current ADA Standards for circular turning space.
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....