Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
Search Results "Patient Toilet Room"
-
11B-703.5.5 Character height
-
M304.1 General (Section-by-Section Analysis)
This is an introductory section.
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
Construction Sites: ADA Standard Section 203.2
Section 203.2 covers scoping requirements of general exceptions for construction sites in the most current ADA Standards.
-
11B-612 Saunas and steam rooms
11B-612 Saunas and steam rooms....
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADA Standards] 219.2 Required Systems....
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADA Standards] 219.2 Required Systems....
-
Signage
Error/Omission: Where permanent room identification signage is provided, it is mounted in the wrong location....
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within...
-
M301.3.1 Transfer Supports
For wider tables (>24”), a transfer support would not be usable because of its distance from the patient using a mobility device....
- Big John Commode Chair BJBC
-
5.7.1 Lift Compatibility Clearance in Base for M301
portable floor lifts to be effective, they must deploy at diagnostic equipment such that the boom of the lifts can maneuver far enough over the equipment to safely lower and raise the patient...
-
Printable Room Layouts
include layouts as an addendum to your facility contract, provide them in a pre-meeting with facility and banquet staff, and use them with your internal planning team to ensure that your rooms...
-
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position....
- Mega Jailhouse Vandal Resistant/Security Toilet Paper Holder
-
M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
[See subsections ...]
-
M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
[See subsections ...]
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...
-
4.1.6(4)(e)
(e) Toilet rooms....
-
11B-604.8 Toilet compartments
Wheelchair accessible toilet compartments shall meet the requirements of Sections 11B-604.8.1 and 11B-604.8.3....
- AJW Architectural Products U841 Dual Hooded Toilet Tissue Dispenser w/Auto Reserve - Recessed - Non-Controlled