Re: Parking Scoping at a Police Station
-
R208.2 Where Not Required
Detectable warning surfaces are not required at pedestrian refuge islands that are cut-through at street level and are less than 1.8 meters (6.0 ft) in length in the direction of pedestrian...
-
RV Parking Spaces Within Camping Units With Mobility Features and RV Pull-Up Spaces at Dump Stations [F244.2.3.2.1 and F244.4]
RV parking spaces within camping units with mobility features and RV pull-up spaces at dump stations must comply with the technical requirements for width, surface, and slope of RV spaces...
- Pilot Rock Accessible Park Site Amenities
-
Perpendicular Curb Ramps (R304.2) (Section-by-Section Analysis)
The turning space must be 1.2 meters (4 feet) minimum by 1.2 meters (4 feet) minimum, and is permitted to overlap other turning spaces and clear spaces....
-
Can parking signage height be considered a "safe harbor"?
2010 Standard 502.6 says 60" min. to parking sign bottom. 1991 Standard 4.6.4 said parking signs need to be high enough "so they cannot be obscured by a vehicle parked in the space."...
-
19. Are new play components added to an existing play area required to comply with the Standards even if there is not an accessible route from parking or the street to the play area?
Are new play components added to an existing play area required to comply with the Standards even if there is not an accessible route from parking or the street to the play area?...
-
R402 Protruding Objects (Section-by-Section Analysis)
R402 Protruding Objects (Section-by-Section Analysis) Objects with leading edges between 685 millimeters (2.25 feet) and 2 meters (6.7 feet) above the finish surface must not protrude...
-
R204 Pedestrian Access Routes (Section-by-Section Analysis)
public right-of-way, including accessible pedestrian signals and pedestrian pushbuttons, accessible street furniture, accessible transit stops and transit shelters, accessible on-street parking...
-
Boundaries of Angled Parking Spaces
An architect asked me about allowable slopes in angled parking stalls and whether the "triangular sections" at the head of the stall and the foot of the stall could have slopes > 1:48...
-
11B-809.9.6 Controls
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
Unified Facilities Guide Specifications
02752, Portland Cement Concrete Pavement for Roads and Site Facilities, published by the National Institute of Building Sciences, it is stated that surfaces should be tested with a 4 - meter...
-
36 CFR Part 1191 ABA Accessibility Guidelines, Outdoor Developed Areas
(Forest Service); Department of Defense (Army Corps of Engineers); and Department of the Interior (Bureau of Land Management, Bureau of Reclamation, Fish and Wildlife Service, National Park...
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Common Requirements (R304.5) (Section-by-Section Analysis) The clear width of curb ramp runs (excluding flared sides), blended transitions, and turning spaces must be 1.2 meters (4 feet...
- U.S. Tape Company, Inc. Digi-Pro
-
Trail Slopes
Segments Maximum Length of Segment Between Resting Intervals Steeper than But no Steeper than 1:20 (5 percent) ) 1:12 (8.33 percent) 200 feet (61 meters...
-
Trailheads
Department of the Interior, National Park Service for installing an inaccessible toilet at 10,000 feet (3,048 meters) on Mt. Rainer....
-
Slopes and Resting Intervals for Beach Access Routes
Many visitors can negotiate steeper slopes for short distances, so running slopes up to 1:12 (8.33 percent) are permitted for up to 50 feet (15 meters), and running slopes of up to 1:10...
-
Pedestrian Signal Phase Timing (Section-by-Section Analysis)
Analysis) Pedestrian signal phase timing must comply with referenced MUTCD standards and use a pedestrian clearance time that is calculated based on pedestrian walking speed of 1.1 meters...
-
R215 Passenger Loading Zones (Section-by-Section Analysis)
R215 Passenger Loading Zones (Section-by-Section Analysis) Where passenger loading zones are provided, at least one passenger loading zone for each 30 meters (100 feet) of continuous...
-
R210 Protruding Objects
pedestrian access routes when installing or permitting the installation of street furniture on sidewalks, including street lights, utility poles and equipment cabinets, sign posts and signs, parking...
-
6. Longitudinal Profile Measurement
6.1 The longitudinal profile measurements can be obtained from equipment that operate in a range of speeds from static to meters per second. 6.2 The elevation profile measuring equipment...
-
R208 Detectable Warning Surfaces (Section-by-Section Analysis)
Detectable warning surfaces are not required at pedestrian refuge islands that are cut-through at street level and are less than 1.8 meters (6 feet) in length in the direction of pedestrian...