Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
Search Results "Opening"
-
11B-607.5 Controls
-
11B-608.9 Shower floor or ground surface
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Car Dimensions and Doors: ADA Standard Section 408.4.1
Section 408.4.1 covers the current ADA Standards for the car dimensions and doors of limited-use/limited-application elevators.
-
11B-307.2 Protrusion limits
Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). ◼ ...
-
11B-809.8.3 Door maneuvering clearance.
A 39 inch (991 mm) minimum length is allowed at interior doors when a clear opening width of 34 inches (864 mm) minimum is provided....
-
11B-307.2 Protrusion limits
Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). ◼ ...
-
406.2.2 Clear height
Exception: A lower clear height is permitted for a parking tier in mechanical-access open parking where approved by the building official. Advisory 406.2.2 Clear height....
-
1134A.6 Showers
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or 1.2. ...
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub. [ECTCR UFAS 4.20.7]...
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
§27.71(k)(5)(iii) Captioning.
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
§ 27.71(k)(5)(iii) Captioning
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
Wheelchair accessible seating is required. At least one percent of the seating must be wheelchair seating locations.
Each wheelchair seating location is an open, level space that accommodates one person using a wheelchair and has a smooth, stable, and slip-resistant surface....
-
g-v
If the answers to questions g-ii thru g-iv are No, can the door be propped open? ...
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub....
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
Gates and Barriers on Trails
If gates or barriers are constructed to control access to trails, include openings wide enough to allow hiker passage....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
Automatic Door
A door equipped with a power-operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...