Hand-operated metering faucets shall remain open for 10 seconds minimum....
Search Results "Opening"
-
11B-606.4 Faucets
-
§ 38.63(b) Exception
Between-car barriers are not required where platform screens are provided which close off the platform edge and open only when trains are correctly aligned with the doors....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance. ...
-
Entry Points and Seats
Examples of entry points and seats include swing seats, spring rocker seats, and crawl-tube openings (left)....
-
Paragraph (a) Operable without vision (Section-by-Section Analysis)
Operable without vision (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial changes mentioned in the opening...
-
§ 36.303(g)(10)
(10) This section does not require the use of open movie captioning as a means of compliance with paragraph (g) of this section, even if providing closed movie captioning for digital movies...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1134A.6, Item 1.1
1.1 The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
-
804.6.3 Dishwasher
The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink....
-
1134A.6, Item 1.1
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
-
406.2.2 Clear height
Exception: A lower clear height is permitted for a parking tier in mechanical-access open parking where approved by the building official. Advisory 406.2.2 Clear height....
-
Boat Slip Clearance: ADA Standard Section 1003.3.1
Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
11B-1003.3.1 Boat slip clearance
Each 10 feet (3048 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
11B-1003.3.1 Boat slip clearance
Each 10 feet (3048 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
Paragraph (d) Operable without hearing (Section-by-Section Analysis)
Operable without hearing (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial changes mentioned in the opening...
-
Paragraph (h) Operable without speech (Section-by-Section Analysis)
Operable without speech (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial changes mentioned in the opening...
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2 1/2 inches (64 mm) maximum....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel...
-
FAQ: How do I submit a job for the Job Board?
To submit details of a job opening to add to the Job Board, you may either: 1. Click on the "FEEDBACK OR HELP" button that appears on every page of Corada. 2....
-
4.5.2 Clear Floor or Ground Space
The space shall be positioned for either forward or side approach to the container opening and be adjacent to or overlap the ORAR....