The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
Search Results "Multifamily Dwelling (HUD 504)"
Commonly Searched Documents
-
1132A.8.1 Lever-type hardware
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.4.1, Item 2
2. Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following:
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section.
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following: A minimum linear length of 30 inches (762 mm) of countertop shall be provided for...
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor. Where towel bars are provided they shall be...
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm)...
-
11B-228.2 Mail boxes
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with Section 11B-309 shall be provided for each residential dwelling unit...
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....
-
11B-228.2 Mail boxes
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with Section 11B-309 shall be provided for each residential dwelling unit...
-
Requirement 7 -- Usable Kitchens and Bathrooms
[See subsections ...]
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
A. Yes. For a 36 x 36 shower, as shown in Figure 7(d), a person in a wheelchair would typically add a wall hung seat. Thus the parallel approach as shown in Figure 7(d) is essential...
-
§100.205(c)(3)(iv)
(iv) Usable kitchens and bathrooms such that an individual in a wheelchair can maneuver about the space.
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
7(2)(b)(vii)
If the shower stall is the only bathing facility provided in the covered dwelling unit, or on the accessible level of a covered multistory unit, and measures a nominal 36 x 36, the shower...
-
11B-228.2 Mail boxes
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with Section 11B-309 shall be provided for each residential dwelling unit...