disabilities.114 The school in this scenario is an existing facility because it was built before June 4, 1977, and therefore, program access is required to ensure compliance with Section 504...
Search Results "Multifamily Dwelling (HUD 504)"
Commonly Searched Documents
-
Scenario 8 – Accessibility
-
11B-216.8.1 Geometric symbols
Such spaces include but are not limited to; patient sleeping rooms, transient lodging guest rooms, and residential dwelling units....
-
4.34.2(3)
(3) At least one accessible route complying with 4.3 shall connect the accessible entrances with all accessible spaces and elements within the dwelling units....
-
Section 35.151(e) Social service center establishments
First, for the first time, residential dwelling units are explicitly covered in the 2004 ADAAG in section 233....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation, and carbon monoxide detection...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
1010.1.7 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
In response to these concerns, and mindful that Congress did not intend the accessibility requirements of the Act to override the need to protect the physical integrity of multifamily housing...
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
Section 100.205(c)(3)(ii) requires that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
11B-216.5.1 Parking spaces
In residential facilities, where parking spaces are assigned to specific residential dwelling units, identification of accessible parking spaces shall not be required....
-
11B-216.5.1 Parking spaces
In residential facilities, where parking spaces are assigned to specific residential dwelling units, identification of accessible parking spaces shall not be required....
-
1132A.4 Level floor or landing
1132A.4 Level floor or landing. See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors...
-
1132A.5 Maneuvering clearances at doors
1132A.5 Maneuvering clearances at doors.
-
1133A.4 Countertops
1133A.4 Countertops. Kitchen countertops shall comply with this section and shall be provided with the following:
-
1132A.8.1 Lever-type hardware
1132A.8.1 Lever-type hardware. The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
A. No. The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2.
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors. Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push...
-
1133A.1 General
1133A.1 General. Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
-
1132A.4.1, Item 2
2. Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal...
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink.
-
A4.34.6.6 RANGES AND COOKTOPS
Although not required for minimum accessibility, countertop range units in a counter with adjustable heights can be an added convenience for wheelchair users.
-
A4.34.6.8 REFRIGERATOR/FREEZERS
Side-by-side refrigerator/freezers provide the most usable freezer compartments. Locating refrigerators so that their doors can swing back 180 degrees is more convenient for...