A process by which sediment (usually sand) is added to a beach. An entity is not required to expend more than 20% of the costs of a beach nourishment project to provide a beach...
Search Results "Grab Bar Location"
-
Beach Nourishment
-
6.7.1 Running Slope (Grade)
The running slope (grade) of a Beach Access Route shall comply with all applicable provisions of this section. Table 6.7.1. Running Slope (Grade) and Resting...
-
1018.7 Slopes
The slopes of beach access routes shall comply with 1018.7.
-
1018.6 Openings
Openings in the surface of beach access routes and resting intervals shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1018.6 Openings....
-
F248.1 General
Beach access routes complying with 1018 shall be provided in accordance with F248.1. Beach access routes shall be permanent or removable. EXCEPTION: Beach access routes shall not...
-
10.3.1(6)
(6) Lists of stations, routes, or destinations served by the station and located on boarding areas, platforms, or mezzanines shall comply with 4.30.1, 4.30.2, 4.30.3, and 4.30.5....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
Plan 4B: 13-Foot Wide Accessible Guest Room
inches wide (section 608.2.3); • Alternate roll-in shower has a 36-inch wide entry at one end of the long end of the compartment (section 608.2.3); • Recessed alternate roll-in shower location...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
are provided in the bathroom: • Comparable vanity counter top space (section 806); • Standard roll-in type shower with folding seat (section 608.2.2); • Recessed roll-in shower location...
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The 1991 Standards, at section 9.2.2(7), allow the clear floor space at kitchen sinks and wet bars in transient lodging guest rooms with mobility features to be positioned for either a forward...
-
11B-809.10.2 Number of complying bathrooms and fixtures
Lavatories, vanities, mirrors and towel bars shall comply with Section 11B-809.10.8....
-
11B-216.2 Designations
Exception: Exterior signs that are not located at the door to the space they serve shall not be required to comply with Section 11B-703.2....
-
11B-216.2 Designations
Exception: Exterior signs that are not located at the door to the space they serve shall not be required to comply with Section 11B-703.2....
-
208.3.1 General
Parking spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with 206.4....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
Location....
-
Plan 4A: 13-Foot Wide Accessible Guest Room
roll-in type shower with folding seat (section 608.2.2); • Clear floor space adjacent to shower min. 30 inches wide by 60 inches long (section 608.2.2); • Recessed roll-in shower location...
-
Plan 6B: 12-Foot Wide Accessible Guest Room
(section 607.2); • Recessed lavatory with vanity counter top permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1);...
-
1607.9 Loads on handrails, guards, grab bars, shower seats, dressing room bench and seats
1607.9 Loads on handrails, guards, grab bars, shower seats, dressing room bench and seats....
-
1607.9 Loads on handrails, guards, grab bars, shower seats, dressing room bench and seats
1607.9 Loads on handrails, guards, grab bars, shower seats, dressing room bench and seats....