The upright part between two adjacent stair treads, between either an upper or lower landing and an adjacent stair tread, or between two adjacent landings....
Search Results "Exterior Stair"
-
RISER
-
EXIT
Exit components include exterior exit doors at the level of exit discharge, interior exit stairways, interior exit ramps, exit passageways, exterior exit stairways and exterior exit ramps...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
11B-206.2.8 Employee work areas
Common use circulation paths located within exterior employee work areas that are fully exposed to the weather shall not be required to comply with Section 11B-402....
-
11B-206.2.8 Employee work areas
Common use circulation paths located within exterior employee work areas that are fully exposed to the weather shall not be required to comply with Section 11B-402....
-
III-7.4100 General
This section addresses exterior features such as parking, portable toilets, and exterior signage in new construction....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
4.1.6(1)(d)
For example, if the elevators and stairs in a building are being altered and the elevators are, in turn, being made accessible, then no accessibility modifications are required to the stairs...
- EVAC+CHAIR® 300H (MK-4) Evacuation Chair
-
11B-206.2.3.2 Distance to Elevators
which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp, elevator or lift shall be provided within 200 feet (60,960 mm) of travel of each stair...
-
11B-206.2.3.2 Distance to Elevators
which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp, elevator or lift shall be provided within 200 feet (60,960 mm) of travel of each stair...
-
11B-206.2.3.2 Distance to Elevators
which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp, elevator or lift shall be provided within 200 feet (60,960 mm) of travel of each stair...
-
11B-404.2.4.3 Recessed doors and gates
clearances for forward approach shall be provided when any obstruction within 18 inches (457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior...
-
11B-404.2.4.3 Recessed doors and gates
clearances for forward approach shall be provided when any obstruction within 18 inches (457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior...
-
R409.3 Continuity
Handrails shall be continuous within the full length of each ramp run or stair flight....
-
Surface discontinuities
Elevation changes due to ramps or stairs do not, themselves, constitute surface discontinuities....
- Kompan, Inc. Elements Play Structures Tower ELE400050
-
Temporary Solutions for Election Day - Hallways and Corridors - Voters Who are Blind or Who Have Low Vision
Problem Three: The bottom of a stair is open and voters who are blind or who have low vision can hit their heads on the underside of the stair....
-
704.5 Fire-resistance rating
Exterior walls shall be fire-resistance rated in accordance with Tables 601 and 602....
-
Emergency Evacuation Planning Guide For People with Disabilities
CONTAINS PROVISIONS FOR THOSE WITH: Mobility Disabilities • Blind or Low Vision • Deaf or Hard of hearing • Speech Disabilities • Cognitive...
-
Handrails
Handrails are required along both sides of ramps and stairs....
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
As we’re talking about stairs, one of the worst stairs I’ve ever seen is the main exit stair out of Penn Station in New York....