Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
Search Results "Door Pull"
-
11B-409.3.1 Power operation
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Smooth Surface
Exceptions from this requirement are recognized for sliding doors (Exception 1), certain tempered glass doors without stiles (Exception 2), doors and gates that do not extend to within 10...
- Safety Technology: the First 30 Years
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor...
-
907.2.6 Group I
A manual fire alarm system and an automatic fire detection system shall be installed in Group I occupancies. An electrically supervised, automatic smoke detection system shall be...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm...
-
g-ii
Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able to easily...
-
A2
Is the vehicle pull-up area relatively level (1:50 or 2% maximum slope in all directions)? Yes No...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Entrances
space beyond the latch side of the door....
-
Are spring hinges and gravity hinges considered “closers” in determining the size of maneuvering clearances?
Some approaches require additional maneuvering clearances when a door or gate is equipped with a closer because of the additional force that must be counteracted in proceeding through doors...
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
TAS 404.2.10 also includes Exceptions for (1) sliding doors, (2) tempered glass doors (3) doors and gates which do not extend to within 10 inches of the finish floor, and (4) existing doors...