In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
Commonly Searched Documents
-
11B-606.3 Height
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
§ 36.406(d) Social service center establishments.
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units that are subject...
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
-
Residential Facilities
units to provide mobility features and at least two percent (2%) of the dwelling units to provide communication features....
-
Multiple Camping Unit
Multiple Camping Unit. A camping unit that can accommodate more than 5 PAOT. A double camping unit accommodates 10 PAOT. A triple camping unit accommodates 15 PAOT. ...
- Bradley 2-Stall Seat Cover/Tissue Dispenser 5921
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
206.2.3 Multi-Story Buildings (Exception 4), F206.2.3 Multi-Story Buildings (Exception 4)
In facilities with residential dwelling units, an accessible route shall not be required to connect stories where residential dwelling units with mobility features required to comply with...
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
In such case, the surface should be no more than 4 inches below the floor level of the interior dwelling unit, unless the local code requires a lower drop....
-
Bobrick TrimLineSeries Recessed Seat-Cover Dispenser B-3013
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick MatrixSeries Seat-Cover Dispenser B-5221 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Surface Mounted Seat Cover Dispenser 5831 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
5.3 Employment Agencies
5.3 Employment Agencies Employment agencies are "covered entities" under the ADA, and must comply with all ADA requirements that are applicable to their activities....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...