4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
-
Flush Controls: ADA Standard Section 604.9.5
Section 604.9.5 covers the current ADA Standards for flush controls on children's use water closets.
-
3(2)
(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
-
Doorways [4.8.4]
Recommendation: Ramps and doors should be configured to facilitate wheelchair maneuvering and to prevent open doors from obstructing ramp openings (important along egress routes)....
-
239.3 Miniature Golf Course Configuration
EXCEPTION: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
11B-239.3 Miniature golf course configuration
Exception: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
F239.3 Miniature Golf Course Configuration
EXCEPTION: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
239.3 Miniature Golf Course Configuration
EXCEPTION: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
2.4.4.1. Repair Costs
For the most part, if equipment breaks down, the answer is replacement rather than repair. Such costs are captured by the hardware and device replacement costs (Section 3.6). ...
-
Slope [§405.2] and Cross Slope [§405.3]
Variations in slope, such as grade breaks within runs, can disrupt wheelchair travel....
-
11B-239.3 Miniature golf course configuration
Exception: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
11B-239.3 Miniature golf course configuration
Exception: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
Height: ADA Standard Section 611.4
Section 611.4 covers the current ADA Standards for the height of the laundry compartment in top loading machines and front loading machines.
-
11B-611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (381 mm) minimum and 36 inches (914 mm) maximum above the finish floor....
-
Kitchen Appliances and Fixtures
Universal kitchen utensils (can opener, spatula, peeler, etc.) Ready-Hot faucet for sterilizing. ...
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-409.3.1 Power operation
Power operated doors and gates shall remain open for 20 seconds minimum when activated....
-
11B-409.3.1 Power operation
Power operated doors and gates shall remain open for 20 seconds minimum when activated....