The Access Board sought public input with question 30 in the MDE NPRM preamble, on whether there is diagnostic equipment with wheelchair spaces on raised platforms that does not provide...
Search Results "Wheelchair Space (Assembly)"
Commonly Searched Documents
-
5. Edge Protection
-
Purchase of multiple tickets. (Section-by-Section Analysis)
There are various ways that covered entities can accommodate groups that require at least one wheelchair space. ...
-
5.8.2.7 Base Support Allowance
Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½ inches high....
-
Clear Floor or Ground Space: ADA Standard Section 805.3
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
- Access Board: T-Shaped Space
-
A4.2.3 WHEELCHAIR TURNING SPACE
This standard specifies a minimum space of 60 in (1525 mm) diameter for a pivoting 180-degree turn of a wheelchair....
-
A4.2.3 Wheelchair Turning Space
These guidelines specify a minimum space of 60 in (1525 mm) diameter or a 60 in by 60 in (1525 mm by 1525 mm) T-shaped space for a pivoting 180-degree turn of a wheelchair....
-
§382.131 Do baggage liability limits apply to mobility aids and other assistive devices?
With respect to transportation to which 14 CFR part 254 applies, the limits to liability for loss, damage, or delay concerning wheelchairs or other assistive devices provided in part 254...
-
Some wheelchairs weigh more than 600 pounds when occupied, and the design load of the lifts on our vehicles is 800 pounds. Is a transportation operator required to carry these “overweight” wheelchairs?
Transportation operators must carry a wheelchair and occupant if the lift and vehicle can physically accommodate them....
-
§ 35.138(h)(2)
(2) For season tickets, subscriptions, or other multi-events, it is permissible to ask the individual to attest in writing that the wheelchair space is for an individual who utilizes a wheelchair...
-
Wheeled Mobility Anthropometry Project
, power wheelchairs, and scooters....
-
11B-802.4.2 Identification
If there is no ticket office, the functional equivalent would be in the lobby or at the entrance to the assembly area in a conspicuous location. ◼...
-
Battery-powered Wheelchairs
Battery-powered Wheelchairs Carriers must accept a passenger’s battery-powered wheelchair, including the battery, as checked baggage unless baggage compartment size and aircraft airworthiness...
- Amos Winter: The cheap all-terrain wheelchair | TED Talks
-
The carrier must designate priority stowage space for at least one wheelchair in the closet or other stowage area
If there is a closet or other approved stowage area for passengers’ carry-on items of sufficient size to accommodate a folding, collapsible, or break-down wheelchair, the carrier must...
-
382.129 What other requirements apply when passengers’ wheelchairs, other mobility aids, and other assistive devices must be disassembled for stowage?
382.129 What other requirements apply when passengers’ wheelchairs, other mobility aids, and other assistive devices must be disassembled for stowage?...
-
ELECTRIC VEHICLE CHARGING SPACE (EV Space)
A space intended for charging electric vehicles....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
- AccessRec All Terrain PVC Beach Chairs
-
1. Background
., 2002) However, in an active and highly accessible environment, such as the convention centers and cities where they hold the National Veterans Wheelchair Games (NVWG), WC users can travel...
-
4.2.3* Wheelchair Turning Space
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
4.2.3* WHEELCHAIR TURNING SPACE
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
3. Exception to Ramp Running Slope
The MDE NPRM proposed that where there is a change in level at the entry of a wheelchair space that is greater than 1½ inches, the entry shall be ramped and have a running slope not steeper...
-
11B-305 Clear floor or ground space
[See subsections ...]