11B-805.4.3 Turning space
-
1002.3 Load and Unload Areas
A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas....
-
1002.3 Load and Unload Areas
A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas....
-
Is compliance required for parking spaces designed specifically for recreational vehicles such as motor homes and camping or boating trailers?
The ABA Standards, which apply to federally funded sites, provide requirements for outdoor developed areas on federal lands such as camping and picnic facilities that include provisions...
-
Must barriers be removed in areas used only by employees?
Must barriers be removed in areas used only by employees? No....
-
Number and Location: ADA Standard Section 221.2.1
Section 221.2.1 covers scoping requirements in the current ADA Standards for the number and location of wheelchair spaces.
-
Handrail Height: ADA Standard Section 1008.2.5.3.2
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface.
-
11B-221.2.1 Number and location
Wheelchair spaces shall be provided complying with Section 11B-221.2.1.
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.
-
11B-221.2.1 Number and location
Wheelchair spaces shall be provided complying with Section 11B-221.2.1.
- Pilot Rock M-32/17 Campfire Ring
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves. Fire rings with double walls or...
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than asphalt, concrete, or boards, slopes not...
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
Passing Spaces [1016.4]
Where the clear width of an ORAR is less than 60 inches, passing spaces must be provided at intervals of at least 200 feet. Passing spaces must be: A minimum space of 60...
-
Protruding Objects [1016.9]
Objects that protrude into ORARs, passing spaces, and resting intervals can pose hazards to people who are blind or have low vision. Constructed elements, such as signs on ORARs,...
-
6.11 Protruding Objects
Constructed features, including signs, shall not extend into the space above a beach access route more than 4 inches (100 mm) if they are between 27 inches (685 mm) and 80...
-
4.2 Fire Rings, Grills, Fireplaces, and Wood Stoves
[See subsections ...]
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves. Fire rings with double walls or...
-
1011.2.3 Slope
This section requires the slope of the clear ground space to not be steeper than 1:48 in any direction. Where the surface is other than asphalt, concrete, or boards, slopes not...
-
2.5.1 Location
A resting interval shall be provided between each ORAR segment, in compliance with section 2.4.1. Depending on the design and location, the intersection of two ORARs may act as a...
-
4.5.5 Controls and Operating Mechanisms
Controls and operating mechanisms shall comply with the operable parts requirements in sections 308 and 309.4 of the ABAAS. Exception. Trash and recycling containers with hinged...
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48...