While this provision does not necessarily require the addition of electrical outlets, consideration should be given to locating outlets to support dispersion of seating available for individuals...
Search Results "Horizontal Dispersion"
-
11B-219.5 Permanent and portable systems
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (16 mm) and the horizontal...
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
Transfer Supports Location and Configuration M301.3 and M302.3
The shape (contours and curves along length for ergonomics, not cross sectional profile) was kept open to give manufacture flexibility in the design as the direction of positioning (i.e. horizontal...
-
1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (16 mm) and the horizontal...
-
Water closet
In the horizontal or down position, grab bars on both sides of the toilet would permit individuals requiring assistance to maintain balance while clothing was removed or replaced....
-
Slope [§405.2] and Cross Slope [§405.3]
Slope [§405.2] and Cross Slope [§405.3] Slope represents the proportion of vertical rise to horizontal length and is specified in the Standards as a ratio (e.g., 1:12)....
-
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1]
(An exit passageway is a horizontal component of an exit that is separated from interior building spaces by fire-resistance-rated construction that leads to the exit discharge or public...
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-810.5.3 Platform and vehicle floor coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
810.5.3 Platform and Vehicle Floor Coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
11B-810.5.3 Platform and vehicle floor coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
11B-810.5.3 Platform and vehicle floor coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
2. Analysis of footrest clearance height and depth
Three dimensions were computed on the right-side for the sub-set of wheelchairs with footrests: Abdomen-Castor edge depth: measured as the horizontal distance from the abdomen to...
-
ICC/IBC: ADA Standard Section 105.2.4
Section 105.2.4 of the ADA Standards cover references to the International Code Council (ICC) and the International Building Code (IBC).
-
11B-608.6 Shower spray unit and water
Each shower head shall be installed so it can be operated independently of the other and shall have swivel angle adjustments, both vertically and horizontally....
-
11B-608.6 Shower spray unit and water
Each shower head shall be installed so it can be operated independently of the other and shall have swivel angle adjustments, both vertically and horizontally....
- Willoughby Industries US-HC Cabinet Shower
- Guldmann GL5 Mobile Lifter