- Magnuson Group BALLOON Outdoor Waste Receptacle
-
Employee Work Areas: ADA Standard Section 203.9
Section 203.9 covers scoping requirements of general exceptions for employee work areas in the most current ADA Standards.
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
Clear Ground Space [1013.2]
A clear ground space at least 48 inches wide must be provided on all usable sides of tent pads and tent platforms....
-
Water Closet Clear Floor Space
The proposed rule stated that no fixtures (other than the water closet) or obstructions were to be located within the clear floor space (604.3.1)....
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
Clearance: ADA Standard Section 604.3
Section 604.3 covers the current ADA Standards for clearances around water closets and in toilet compartments.
-
Size: ADA Standard Section 604.3.1
Section 604.3.1 covers the current ADA Standards for the size of the water closet clearance.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951....
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
A4.5.1 GENERAL
Cross slopes on walks and ground or floor surfaces can cause considerable difficulty in propelling a wheelchair in a straight line....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-502.4 Floor or ground surfaces
[2010 ADAS] Advisory 502.4 Floor or Ground Surfaces. ...
-
11B-502.4 Floor or ground surfaces
[2010 ADAS] Advisory 502.4 Floor or Ground Surfaces. ...
-
Use Zones: ADA Standard Section 1008.2.6.2
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1)....