A4.28 Alarms
-
Location and Spacing
Location and Spacing Rooms with an area than can be circumscribed by a circle 50 feet in radius can be covered by a single centrally located strobe of 75 cd. For very small rooms,...
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz.
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower. (This can be measured...
-
4.28 Alarms
[See subsections ...]
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum...
-
4.28 ALARMS
[See subsections ...]
-
A4.28.2 AUDIBLE ALARMS
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
A4.28 ALARMS
[See subsections ...]
-
§ 37.43(f)(2)(vi)
(vi) When possible, other accessible elements (e.g., parking, storage, alarms).
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
1010.1.9.1 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
Entrance
One commenter requested clarification on whether "entrance" refers to an entry door to a dwelling unit, or an entry door to the building. Response....
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
9.2.2(3)
(3) Doors and doorways designed to allow passage into and within all sleeping rooms, suites or other covered units shall comply with 4.13....
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
Requirement 3. Usable doors.
Section 100.205(c)(2) provides that covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow...
-
§ 38.25 Doors, steps and thresholds
[See subsections ...]
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Architect
The 4040XP provides adjustments for Position 1-6, has a range of interior and exterior door sizes it can work on....
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....