If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
Search Results "Double Door"
Commonly Searched Documents
-
H5
- Aurora Doors Sliding Barn Door
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
- SOSS Door Hardware UltraLatch Demonstration Video
-
Measuring Opening Force
Measuring Opening Force The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door...
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
- NABCO GT1175 All Glass Sliding Door
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
- PC Doors Pocket Door EZ-Closer
- Cal-Royal CR441 Series Hydraulic Door Closers
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
- AD Systems’ Exam Room Doors
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
- Norton Surface Mounted 5900 Series Low Energy Door Operator
-
11B-603.2.3 Door swing
SECTION TITLE NOTES 11B-603.2.3 Door swing....
- Figure 404.2.4.2(a) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Sargent 351 Series Aluminum Door Closer
- Cal-Royal CR801 Series Hydraulic Door Closers
- BEA's MS21 Touchless Activation Sensor
-
T204.4 Doorways with Steps on Over-the-Road Buses
On over-the-road-buses, doorways with steps shall comply with T502.4.