This example of a retail facility shows how scoping requirements for certain elements and spaces (sales counters and fitting rooms) apply and indicates employee work areas....
Search Results "Counter Depth"
-
Example: Retail Facility
-
806 Transient Lodging Guest Rooms
Substantive changes made to this section revise requirements for: vanity counter spaces in accessible toilet or bathing rooms (806.2.4.1) wheelchair turning space (806.2.6...
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH...
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH...
-
Pass Through Kitchen
Clearances for pass through kitchens address counters, appliances, or cabinets on two opposing sides....
-
3) Restaurants
Contains requirements for counters and bars, access aisles, food service lines, tableware and condiment areas, raised speaker's platforms, and vending machine areas (but not controls)....
-
Side Entry: ADA Standard Section 1002.4.4.2
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
Door Maneuvering Clearance
At doors that provide a latch side approach, the minimum depth of this clearance is increased where a closer is provided because additional space is needed to counteract the force of closers...
-
4.17.3* Size and Arrangement
Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
Water Closet Clear Floor Space in Toilet Compartments
Many comments urged the Board to increase this depth so that at least 48 inches is provided in front of the water closet. Others recommended an overall depth of 78 inches. Response....
- Simple Pump Company ADA 100 Simple Water Pump
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach...
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
11B-705.1.2.4 Bus stops
warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth...
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
-
11B-705.1.2.4 Bus stops
warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth...
-
226.1 General
Sales counters and service counters shall not be required to comply with 902. 2....
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ...
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....