Floor surfaces on aisles, places for standees, and areas where wheelchair and mobility aid users are to be accommodated shall be slip-resistant.
Search Results "Commuter Rail Car"
-
§ 38.59 Floor surfaces
-
§ 38.77 Interior circulation, handrails and stanchions
[See subsections ...]
-
§ 38.83(c)(1) Design load
(1) Design load. Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26...
-
§ 38.83(c)(7) Stowage
(7) Stowage. A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridges plates...
-
§ 38.57 Interior circulation, handrails and stanchions
[See subsections ...]
-
§ 38.83(c)(6) Attachment
(6) Attachment—
-
§ 38.83(c) Vehicle ramp or bridge plate
(c) Vehicle ramp or bridge plate—
-
§ 38.83(b)(2) Controls
(2) Controls—
-
§ 38.83(b)(12) Use by standees
(12) Use by standees. Lifts shall accommodate persons using walkers, crutches, canes or braces or who otherwise have difficulty using steps. The lift may be marked to indicate a...
-
§ 38.83(b)(3) Emergency operation
(3) Emergency operation. The lift shall incorporate an emergency method of deploying, lowering to ground level with a lift occupant, and raising and stowing the empty lift if the...
-
§ 38.83(b)(1) Design Load
(1) Design load. The design load of the lift shall be at least 600 pounds. Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which the lift...
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
810.6.3 Station Names
810.6.3 Station Names. Stations covered by this section shall have identification signs complying with 703.5. Signs shall be clearly visible and within the sight lines of standing...
-
810.6.3 Station Names
Stations covered by this section shall have identification signs complying with 703.5. Signs shall be clearly visible and within the sight lines of standing and sitting passengers...
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5.
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5.
-
Transportation Facilities: ADA Standard Section 217.4.7
Section 217.4.7 covers scoping requirements in the current ADA Standards for TTYs in transportation facilities.
-
11B-218.5 Other transportation facilities
In other transportation facilities, public address systems shall comply with Section 11B-810.7 and clocks shall comply with Section 11B-810.8.
-
11B-218.5 Other transportation facilities
In other transportation facilities, public address systems shall comply with Section 11B-810.7 and clocks shall comply with Section 11B-810.8.
-
Other Transportation Facilities: ADA Standard Section 218.5
Section 218.5 covers scoping requirements in the current ADA Standards for other transportation facilities.