Search Results "Sloped Sidewalk"
- DSA Drawing 11B-406-5 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
-
DSA Drawing 11B-406-1 Perpendicular Curb next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-4 Perpendicular Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3)....
-
II-6.6000 Curb ramps
When streets, roads, or highways are newly built or altered, they must have ramps or sloped areas wherever there are curbs or other barriers to entry from a sidewalk or path....
- Access Board: Accessible Parking Spaces and Access Aisles
-
DSA Drawing 11B-406-3 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
R304.1 General
There are two types of curb ramps: • Perpendicular curb ramps have a running slope that cuts through or is built up to the curb at right angles or meets the gutter break at right angles...
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis) Parallel curb ramps have a running slope that is in-line with the direction of sidewalk travel and lower the sidewalk to a level...
-
E. What are the General Requirements for Curb Ramps in the ADA Standards for Accessible Design?
slope must generally be 8.33 percent (1:12) or less....
-
9.b [§ 4.7.5]
9.b [§ 4.7.5] If the sidewalk at the top of the ramp (“x”) is less than 48 inches wide and the curb ramp you are surveying has flared sides, answer this question....
-
11B-233.3.1.2.6.2 Test number one, individual building test
of these requirements, vehicular or pedestrian site arrival points include public or resident parking areas, public transportation stops, passenger loading zones and public streets or sidewalks...
-
21. Please indicate the typical slope the particular trail has prior to trail installation
Please indicate the typical slope the particular trail has prior to trail installation: Up to 5% Between 5% (1:20) and 8.33% (1:12) Between 8.33% (1:12) and 10% (1:10) Between 10%...
-
§ 38.23(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches, and the transition from roadway or sidewalk...
-
Section 35.151(i) Curb ramps
Upon further consideration, however, the Department has concluded that the regulation should acknowledge that there are times when there are transitions from sidewalk to road surface that...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
CURB RAMP
A sloping pedestrian way, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
CURB RAMP
A sloping pedestrian way, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
CURB RAMP
A sloping prepared surface, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
Temporary Solutions For Emergency Sheltering - Ramps
Temporary Solutions For Emergency Sheltering - Ramps Problem: The sidewalk connecting parking to the shelter entrance is too steep to be accessible....
- Disability Rights Advocates 2017 Gala Video
-
§ 38.159(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75 mm), and the transition from roadway...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...