In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
Search Results "Sign Clear Floor Space"
Commonly Searched Documents
-
608.5.3 Alternate Roll-In Type Shower Compartments
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
4.10.4 HALL LANTERNS
Visible signals shall have the following features: (1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor....
-
4.21.4 Grab Bars
ADAAG specifies grab bars on the three walls of a roll-in shower stall, 33"-36" above the floor. The plans reviewed offered little insight as to placement of grab bars in showers....
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
Stairs
At the top, the extension shall be parallel with the floor or ground surface....
-
11B-608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
1009.3.3 Area of Refuge
Stairways shall either incorporate an area of refuge within an enlarged floor-level landing or shall be accessed from an area of refuge complying with Section 1009.6....
-
Side reach (Section-by-Section Analysis)
The table accompanying section 217.2 of the 2010 Standards makes clear that where one or more telephones are provided on a floor, level, or an exterior site, only one phone per floor, level...
-
Side reach (Section-by-Section Analysis)
The table accompanying section 217.2 of the 2010 Standards makes clear that, where one or more telephones are provided on a floor, level, or an exterior site, only one phone per floor, level...
-
Valet Parking and Mechanical Access Parking Garages
The 1991 Standards contained an exception that exempted valet parking facilities from providing accessible parking spaces. The 2010 Standards eliminate this exception....
-
Accessible Restrooms, Fitting Rooms, and Elevators
They cannot be used as temporary storage areas or staff locker space....
-
Technical Memorandum TM 2012-03 Shopping Centers or Shopping Malls
In other words, the type of spaces provided on a mezzanine level does not alleviate the obligation to provide the required accessible route....
-
Identification of available accessible seating. (Section-by-Section Analysis)
The proposed rule specifically prohibits the practice of "steering" individuals with disabilities to certain wheelchair spaces so that the facility can maximize potential ticket sales for...
-
711.3.1 Through penetrations
Exception: Where the penetrating items are steel, fer- rous or copper pipes or steel conduits, the annular space between the penetrating item and the fire-resistance- rated wall shall be...
-
Technical Memorandum TM 2013-16 Residential Amenity Centers
TM 2013-16 Residential Amenity Centers Effective Date: June 1, 2013 2012 TAS Reference: 68.30(5) Areas, elements, and spaces in residential amenity centers used exclusively...
-
Openings in Trail Surfaces
Gaps include slots in a drainage grate and spaces between the planks on a puncheon, bridge, or boardwalk....
-
227 Sales and Service
Different 7.3 Check-out Aisles Exception: In alterations, at least one check-out aisle shall be accessible in facilities under 5000 square feet of selling space...
-
ACTIONS TAKEN BY CITY OF WAUKEGAN
During the 2000 fiscal year, they also provided accessible counter space to the counters where city services are provided....
-
Construction Specification Institute
longitudinal lines, measurements were to be taken in minimum 5 - foot lengths running parallel to the long dimension, with one measurement line per 3 feet of width and within 2 feet of edges, spaced...