In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
Search Results "Clear Floor Area"
-
608.5.2 Standard Roll-In Type Shower Compartments
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
Tactile Signage
Examples include signs labeling restrooms, exits, rooms/floors by number or letter. Recommendation: Tactile signs are recommended for room names not likely to change....
-
4.17.3* Size and Arrangement
If the depth of a standard toilet stall is increased at least 3 in (75 mm), then a floor-mounted water closet may be used....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
4.10.4 HALL LANTERNS
Visible signals shall have the following features: (1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor....
-
4.21.4 Grab Bars
ADAAG specifies grab bars on the three walls of a roll-in shower stall, 33"-36" above the floor. The plans reviewed offered little insight as to placement of grab bars in showers....
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
Stairs
At the top, the extension shall be parallel with the floor or ground surface....
-
11B-608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
This clearance would allow the fingers and knuckles to clear adjacent equipment parts as they grip the support....
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
The turning space must be 1.2 meters (4 feet) minimum by 1.2 meters (4 feet) minimum, and is permitted to overlap other turning spaces and clear spaces....
-
Broad Coverage
The ADA Amendments Act cleared up the confusion by stating that bodily functions are indeed major life activities....
-
12. Grievance procedure
A sentence was also added to make clear that grievance procedures are not required to be made available to unsuccessful applicants for employment or to applicants for admission to colleges...
-
2. How may an employer identify individuals who may require assistance?
An employer also may periodically survey all of its current employees to determine whether they will require assistance in an emergency, as long as the employer makes it clear that self-identification...
-
Contractual arrangements with private entities. (Section-by-Section Analysis)
For that reason, the proposed § 35.152(a) makes it clear that this section's requirements will apply to prisons operated by public entities directly or through contractual or other relationships...
-
Elevated Dune Crossings
The clear width of elevated dune crossings may be narrower than the rest of the beach access route, but must be at least 48 inches (1,220 millimeters)....
-
(4) Adjustability: Method of Measurement
the height of the transfer surface for both diagnostic equipment used in the supine, prone, or side-lying position and diagnostic equipment used in the seated position, be taken from the floor...