The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
Search Results "Surface Hazard"
Commonly Searched Documents
-
T503.3 Steps at Front Doorways
- Choosing Level Size
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1017.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
- AccessRec Mr. Boardwalk Modular Walkway
-
2.5.4 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
Section F: Voting Area
_______________________ Location name:______________________ F Within the Voting Area Yes No N/A Comments/Remedies F1 Are floor surfaces...
-
Engineered Wood Fiber
In addition, there were five sites surfaced with a combination PIP and EWF, and eight sites surfaced with a combination TIL and EWF. ...
-
Cross Slope (R302.6) (Section-by-Section Analysis)
In exterior environments, a maximum cross slope of 2 percent is generally accepted as adequate to allow water to drain off paved walking surfaces....
-
1015.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
- Guide for Home Remodeling for People with Disabilities and Special Needs: What You Need to Know
-
(4) Adjustability: Method of Measurement
The MDE NPRM proposed that the measurement of the height of the transfer surface for both diagnostic equipment used in the supine, prone, or side-lying position and diagnostic equipment...
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
-
4.1.2(17)
(17) If fixed or built-in seating, tables, or work surfaces are provided in accessible spaces, at least 5 percent, but always at least one, of seating spaces, tables, or work surfaces shall...
- Smith System Lift Desk Work Surface with Crank
- Husky 10" Multi-Function Standard Digital Level
- Sears Brands, LLC Craftsman 10 in. Digital LaserTrac® Level
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel....
-
7.2.2.1 Determining Impracticability
The surface is not firm and stable for a distance of 45 feet or more (14 m). Limiting Factor 3. ...
-
Seat Width Evaluation
many participants (the 25th through 95th percentiles) for their level, highest and lowest height transfer regardless of the presence or absence of grab bars or a backrest on the transfer surfaces...