Clear floor space at kitchens shall comply with the following:...
Search Results "Space"
Commonly Searched Documents
- 
    
  
  1133A.2 Clear floor space
  
 - 
    
  
  Width [4.3.3.] and Passing Space [4.3.4]
  
However, the minimum width of hallways and corridors is often further determined by ADAAG requirements for clear floor space at elements such as drinking fountains, door maneuvering clearances...
 - 
    
  
  1009.6.3 Size
  
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 48 inches (762 mm by 1219 mm)....
 - 
    
  
  Wheelchair Passage Width [4.2.1] and Passing Space [4.2.2]
  
A minimum width of 30 inches is generally sufficient for stationary space. Additional clearance is needed for maneuvering and sway....
 - 
    
  
  Lines of Sight for Wheelchair Spaces
  
Section 221.2.3 covers dispersion of wheelchair spaces and lines of sight....
 - 
    
  
  11B-703.2.8 Line spacing
  
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height. [S.H. ...
 - 
    
  
  703.5.9 Line Spacing
  
703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
 - 
    
  
  Machinery Spaces (§203.5)
  
Machinery Spaces (§203.5) Spaces used only by service personnel for maintenance, repair, or occasional monitoring of equipment Examples: elevator pits/ penthouses, mechanical/...
 - 
    
  
  11B-406.3.2 Turning space
  
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
 - 
    
  
  12162(a)(3)(A)(ii) a number of spaces
  
(ii) a number of spaces...
 - 
    
  
  Accessible Ground Surfaces
  
Accessible Ground Surfaces Ground surfaces along accessible routes, clear floor or ground spaces, and maneuvering spaces, must comply with the American Society for Testing and Materials...
 - 
    
  
  4.3.3 Clear Floor Area 
  
4.3.3 Clear Floor Area Clear floor area dimensions are the basis for the minimum required size of spaces used by wheeled mobility users (e.g. platform/wheelchair lifts) and for spaces...
 - 
    
  
  Vertical Dispersion: ADA Standard Section 221.2.3.2
  
Section 221.2.3.2 covers scoping requirements in the current ADA Standards for vertical dispersion in assembly areas.
 - 
    
  
  11B-813.2.9 Overlap
  
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
 - 
    
  
  603.2.3 Door Swing
  
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
 - 
    
  
  503.2 Vehicle Pull-Up Space
  
Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) wide minimum and 20 feet (6100 mm) long minimum....
 - 
    
  
  11B-304 TURNING SPACE
  
[See subsections ...]
 - 
    
  
  11B-304 Turning space.
  
[See subsections ...]
 - 
    
  
  11B-304 Turning space
  
[See subsections ...]
 - 
    
  
  General: ADA Standard Section 226.1
  
Section 226.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dining surfaces and work surfaces.
 - 
    
  
  503.2 Vehicle Pull-Up Space
  
Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) wide minimum and 20 feet (6100 mm) long minimum. [ECTCR UFAS 4.6.5]...
 - Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips – Drawing from the U.S. Access Board
 - Figure 1003.3.2 (Exception 1) Clear Pier Space Reduction at Boarding Piers – Drawing from the U.S. Access Board
 - 
    
  
  Beds: ADA Standard Section 807.2.3
  