Unglazed ceramic mosaic tile for slip resistance Sink adaptable to a seated position Reinforcement for ceiling lift from the bed to the bathtub and toilet Grab...
Search Results "Sink Depth"
Commonly Searched Documents
-
Master Bath
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH...
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH...
-
3. FIXTURES and HARDWARE
Other fixtures and hardware can also prevent and/or limit access within medical exam and treatment rooms such as: Accessible coat hooks, Shelves, Sinks and faucets...
-
Side Entry: ADA Standard Section 1002.4.4.2
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
Door Maneuvering Clearance
At doors that provide a latch side approach, the minimum depth of this clearance is increased where a closer is provided because additional space is needed to counteract the force of closers...
-
4.17.3* Size and Arrangement
Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....
-
Water Closet Clear Floor Space in Toilet Compartments
Many comments urged the Board to increase this depth so that at least 48 inches is provided in front of the water closet. Others recommended an overall depth of 78 inches. Response....
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach...
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
11B-705.1.2.4 Bus stops
warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth...
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
-
11B-705.1.2.4 Bus stops
warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth...
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ...
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
102 Dimensions for Adults and Children
requirements are also provided based on children’s dimensions and anthropometrics for drinking fountains, water closets and other elements located in toilet compartments, lavatories and sinks...
-
11B-606.6 Adjacent side wall or partition
ETA Editor's Note The positioning requirement prescribed by CBC 11B-606.6 applies to lavatories, not to sinks....
-
M305.2.2.1 End Transfer Supports
Transfer supports shall be positioned along 13 ½ inches (345 mm) minimum of the depth of the transfer surface....
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed footrest to allow for a left or right transfer....
-
11B-604.5.2 Rear wall
Application Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.5.2: CBC Section 1224.14.2.7 requires the provision of a flushing-rim clinical sink...
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
4.17.4 Toe Clearances
If the depth of the stall is greater than 60 in (1525 mm), then the toe clearance is not required....