ADAEZ Pro Plus Automatic Door Opener Installing Door Operator and Door Arm Video...
Search Results "Self-Closing Door"
Commonly Searched Documents
- ADAEZ Pro Plus Automatic Door Opener Installing Door Operator and Door Arm Video
-
407.3.6 Width
The width of elevator doors shall comply with Table 407.4.1....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
1132A.3, Item 1
Doors shall not be less than 6 feet 8 inches (2032 mm) in height....
-
1132A.3, Item 1
Doors shall not be less than 6 feet 8 inches (2032 mm) in height....
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital....
-
Car Dimensions: ADA Standard Section 407.4.1
Section 407.4.1 covers the current ADA Standards for elevator car dimensions.
- Besam SL500 A01 sliding door with outstanding performance
-
A. Door Width
Door Width....
-
3(2)
between the face of the door and the stop, would meet this requirement....
-
1132A.8 Hand-activated door hardware
1132A.8 Hand-activated door hardware. Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
Standard Stall
The clearances required for stall doors are different than those specified for conventional passage doors and gates in 4.13.6 since partition doors are generally lighter and easier to open...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Smooth Surface
Exceptions from this requirement are recognized for sliding doors (Exception 1), certain tempered glass doors without stiles (Exception 2), doors and gates that do not extend to within 10...
-
3.2.3. Baseline by Venue Type
This section explains how the auditoriums equipped to provide closed movie captioning or audio description are distributed by venue type (Section 2.1.4)....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close....
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close....
-
Notice Requirement (Section-by-Section Analysis)
Several commenters recommended that the Department require a uniform system of labeling movies as having open captioning (OC), closed captioning (CC), or audio description (AD). ...
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....