II−8.4000 Notice to the public. A public entity must provide information on title II's requirements to applicants participants, beneficiaries, and other interested persons. The...
Search Results "Self-Closing Door"
Commonly Searched Documents
-
II-8.4000 Notice to the public
-
§ 36.303(g)(2) General
A public accommodation shall ensure that its movie theater auditoriums provide closed movie captioning and audio description whenever they exhibit a digital movie that is distributed with...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
-
B. The 2010 Advance Notice of Proposed Rulemaking on Captioning and Video Description
Notice of Proposed Rulemaking, Nondiscrimination on the Basis of Disability; Movie Captioning and Video Description, 75 FR 43467 (July 26, 2010) (2010 ANPRM), specifically addressing “closed...
-
Guestroom Doors
Guestroom Doors Common Problem: Doors and doorways into and within all guestrooms and suites, including bathroom doors and doorways, do not allow 32 inches of clear opening width....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
D3. Door Hardware
Is the door hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist?...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
G. Door Hardware
Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching...
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
-
407.3.6 Width
The width of elevator doors shall comply with Table 407.4.1. EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted....
-
407.3.6 Width
The width of elevator doors shall comply with Table 407.4.1. EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted....
-
Door Opening Force [4.13.11]
[See subsections ...]
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....