The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
Search Results "Rail Vehicle"
-
§ 38.159(c)(3) Ramp threshold
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
§ 38.95(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...
-
11B-812.7.2 Marking
Access aisles at vehicle spaces shall be marked with a painted borderline around their perimeter....
-
Section 37.165 Lift and Securement Use
An entity's vehicle is not required to pick up a wheelchair user when the securement locations are full, just as the vehicle may pass by other passengers waiting at the stop if the bus is...
-
§ 38.111(a)(5)
(5) Restrooms, complying with §38.123 shall be provided in single-level rail passenger coaches and food services cars adjacent to the accessible seating locations required by paragraph (...
-
Is there an official review and approval process under the ADA for alternatives pursued as an “equivalent facilitation”?
There is an official review and approval process under the ADA only for transportation facilities (and vehicles) subject to DOT’s ADA regulations, which establish a process for determining...
-
Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
A 1:6 maximum for non-rail vehicle ramp slopes, in their view, was safer and more in line with current technology....
-
§ 37.91 Wheelchair locations and food service on intercity rail trains
[See subsections ...]
-
ADA & Level Boarding - Perfromance [sic] Standards on Station-by-Station Basis
49 CFR §37.42(d)(2) DECEMBER 14, 2011
-
12162(a)(4) Food service
(4) Food service
-
A10.3 Fixed Facilities and Stations
[See subsections ...]
-
10.3 Fixed Facilities and Stations
[See subsections ...]
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches. At the top and bottom of each escalator run, at least two contiguous treads...
-
10.3.1(14)
(14) Where public address systems are provided to convey information to the public in terminals, stations, or other fixed facilities, a means of conveying the same or equivalent...
-
§ 38.113(a)(1)
(1) At least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this...
-
§ 38.113(d)(2) Exception
(2) Exception. New cars operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height.
-
§ 38.115(b)
(b) Where provided, handrails and stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with...
-
§ 38.113(a)(2)
(2) Doorways at ends of cars connecting two adjacent cars, to the maximum extent practicable in accordance with regulations issued under the Federal Railroad Safety Act of 1970 (49...
-
§ 38.95(c)(6) Attachment
(6) Attachment—.
-
§ 37.131 Service criteria for complementary paratransit
[56 FR 45621, Sept. 6, 1991, as amended at 61 FR 25416, May 21, 1996; 71 FR 63266, Oct. 30, 2006]
-
§ 38.121(a)
(a) Each car shall be equipped with a public address system permitting transportation system personnel, or recorded or digitized human speech messages, to announce stations and...
-
§ 38.95(c) Car ramp or bridge plate
(c) Car ramp or bridge plate—