Meets and Exceeds ANSI Standard 156.4 Grade 1 Universal Hole Pattern Offering Versatility And Precision Engineering For New And Retrofit Market Multi Size Adjustable Commercial Door...
Search Results "Door Delay"
Commonly Searched Documents
- Cal-Royal 300 Series Hydraulic Door Closers
-
206.5.4 Residential Dwelling Units
In residential dwelling units required to provide mobility features complying with 809.2 through 809.4, all doors and doorways providing user passage shall comply with 404....
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
D6. Vestibule Clear Floor Space
[ADA Stds 4.13.7] Yes _____ No _____ If No, leave the inner door open or remove inner door, add power operators to both doors so they open at the same time or, modify the vestibule...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
- Cal-Royal 900 Series Hydraulic Door Closers
- Stanley QDC 200 Series Grade 1 Heavy Duty Door Closers
- Stanley QDC 300 Series Grade 1 Standard Duty Door Closers
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
- Cal-Royal CR441 Series Hydraulic Door Closers
- ADAEZ Pro Plus Automatic Door Opener Installation Video
-
D4
On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated?...
-
Requirement 3 -- Usable Doors
[See subsections ...]
-
Guest Rooms
This applies to all doors, including bathroom doors that allow full user passage....
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...