Space required for three-point turn. Lateral operating space (sweep width). Turning radii. Acceleration capabilities. Speed....
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
FIELD DATA COLLECTION PLAN
-
5.1 Architectural Barriers Act (ABA).
5.1.2.1.2 The alteration of an existing building if the alteration does not involve the installation of, or work on, existing stairs, doors, elevators, toilets, entrances, drinking fountains, floors...
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System
- Spectrum Aquatics Gallatin Water Powered Assisted Access Lift
- Nova Health Products LiteRamp 10' Wheelchair and Scooter Ramp (LR10)
- Nova Health Products LiteRamp 7' Wheelchair and Scooter Ramp (LR7)
- AJW Architectural Products UG120-U Series UG120-U 29" Swing-Up, 1.25" Diameter Grab Bar - Configuration U
- Nova Health Products LiteRamp 8' Wheelchair and Scooter Ramp (LR8)
- Endorphin 355 Series e4 Resistance System
- TownSteel ED6500 Narrow Stile Panic Rim Device
- Unity Surfacing Systems Play-Land Safety Surfacing
- Protege Fixed Wheelchair Lift 5442F
- Virtuoso Portable Wheelchair Lift 5460P
- TownSteel ED1100F Grade 1 Fire Rim Device
- Macro Supa-Trac Heavy Duty Ground Surface
- Inpro Corporation ENDURANT® Trench Drain Receptor
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
1117B.1, Item 5
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
1117B.1, Item 4
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
Wheelbase Definition
Wheelbase Definition For the purpose of this analysis, wheelbase is defined as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor...
-
Which Circulation Paths Are Usable Circulation Paths?
In addition, simple floor plans of the building that show the locations of and routes to usable circulation paths should be available and given to visitors with limited mobility when they...
-
3.3.15.1 Forward reach – unobstructed
of the power chair users and 48% of the scooter users could reach beyond their mobility device or foot for at least one point between 600 mm (23.6 in.) and 1100 mm (43.3 in.) from the floor...