In addition to entrances required by F206.4.2 through F206.4.9, at least 60 percent of all public entrances shall comply with 404....
Search Results "Accessibility Requirement"
-
F206.4.1 Public Entrances
-
Minimum Clear Headroom
The specification for minimum clear headroom of 80 inches was included in the proposed guidelines because it is a specification included in the major accessibility codes....
-
Edge Protection
ADAAG addresses drop-offs along ramps and ramp landings but not along other portions of accessible routes or circulation paths....
-
Mirrors [4.19.6]
Mirrors [4.19.6] ADAAG does not require a mirror above the lavatory but requires that if mirrors are provided, at least one must be accessible....
-
Paragraph (d) (Advisory Guidance)
Individuals who are deaf or hard of hearing cannot locate or identify controls that require hearing....
-
68.53. Corrective Modifications Following Inspection
effective November 5, 2001, 26 TexReg 8807; amended effective February 1, 2005, 30 TexReg 382; amended effective March 1, 2007, 32 TexReg 884) (a) When corrective modifications are required...
-
Elevators
Result: People with disabilities who are unable to use stairs and steps cannot gain access to floors above and below the ground level and, in many instances, do not have access to the...
-
Section 37.87 Purchase or Lease of Used Intercity and Commuter Rail Cars
Section 37.87 Purchase or Lease of Used Intercity and Commuter Rail Cars The section also parallels closely the requirements in the ADA for the purchase or lease of accessible used rail...
-
11B-213.3.6 Bathing facilities
Where two or more accessible showers are provided within the same functional area, at least one shower shall be opposite hand from the other or others (that is, one left-hand controls versus...
-
1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
1115B.4.4.8, Item 1
SECTION 1115B BATHING AND TOILET FACILITIES (SANITARY FACILITIES) 1115B.4 Accessible fixtures. 1115B.4.4 Accessible showers. ...
-
Continuous Width (R302.3) (Section-by-Section Analysis)
Where sidewalks are wider than 1.2 meters (4 feet), only a portion of the sidewalk is required to comply with the technical requirements in R302.3 through R302.7....
-
Introduction of new § 35.152 for detention and correctional facilities. (Section-by-Section Analysis)
The proposed rule at § 35.152 is intended to address these frequent problems for inmates with disabilities by: 1) Proposing specific requirements to ensure accessibility when a correctional...
-
NPRM
The NPRM would have required that railroads use level-entry boarding as the preferred means of ensuring nondiscriminatory access....
-
Dimensions for Adults and Children [§102]
The ADA Standards also include requirements for play areas (§240 and §1008) and recommendations (advisory notes) with respect to children’s reach ranges (§301.1) and ramp handrails used...
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
This is consistent with the requirement in the existing accessibility guidelines and standards....
-
Entrances
Temporary Solutions The use of temporary ramps can provide access over steps or high thresholds....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The clear floor space must be positioned for a parallel approach to the side of the bed and must be on an accessible route....
-
11B-805.7 Built-in cabinets and work surfaces
Exceptions: Built-in wardrobes in patient bedrooms and resident sleeping rooms not required to be accessible are not required to comply with the provisions of this chapter....
-
M301.4.2 Clearance Around Base (Section-by-Section Analysis)
The MDE Advisory Committee did not address this provision, and thus provided no recommendations on the clearance around the base requirements....
-
Background
Background June 20, 2007, the Access Board issued proposed guidelines for outdoor developed areas that include requirements for newly constructed or altered trails....