- Figure 410.6 Platform Lift Doors and Gates – Drawing from the U.S. Access Board
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum....
-
11B-410.5 Operable parts
Controls for platform lifts shall comply with Section 11B-309....
-
410.3 Clear Floor Space
Clear floor space in platform lifts shall comply with 305....
-
410.3 Clear Floor Space
Clear floor space in platform lifts shall comply with 305....
-
11B-410.5 Operable parts
Controls for platform lifts shall comply with Section 11B-309....
-
11B-410.5 Operable parts
Controls for platform lifts shall comply with Section 11B-309....
-
410.5 Operable Parts
Controls for platform lifts shall comply with 309....
-
2004 ADA and ABA Accessibility Guidelines
The following technical criteria in the proposed standards are based on the 2004 ADA and ABA Accessibility Guidelines: • Height of transfer surfaces on diagnostic equipment used by patients...
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
12162(a)(2)(C)(i)
(i) be able to be entered from the station platform by an individual who uses a wheelchair; or...
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
A4.16.4 Grab Bars
A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
A4.16.4 GRAB BARS
A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
1007.5.1 Openness
Platform lifts on an accessible means of egress shall not be installed in a fully enclosed hoistway....
-
410.3 Clear Floor Space
Clear floor space in platform lifts shall comply with 305....
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
11B-247.2 Detectable directional texture
At transit boarding platforms, the pedestrian access shall be identified with a detectable directional texture complying with Section 11B-705.2. ...
-
11B-247.2 Detectable directional texture
At transit boarding platforms, the pedestrian access shall be identified with a detectable directional texture complying with Section 11B-705.2....
-
11B-247.2 Detectable directional texture
At transit boarding platforms, the pedestrian access shall be identified with a detectable directional texture complying with Section 11B-705.2....
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
For example, a weight scale with a raised platform for wheelchair use may provide a folding seat and supports for patients who can transfer independently from their mobility device to the...
-
206.2.9.2 Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices
206.2.9.2 Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices....