All handrails, grab bars, and tub and shower seats required to be accessible by 4.1, 4.8, or 4.9 shall comply with 4.26....
Search Results "Handrail Clearance"
-
4.26.1* GENERAL
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
305.7 Maneuvering Clearance
305.7 Maneuvering Clearance....
-
4.26.1* General
All handrails, grab bars, and tub and shower seats required to be accessible by 4.1, 4.8, 4.9, 4.16, 4.17, 4.20 or 4.21 shall comply with 4.26....
-
Dune Crossings [1018.10]
A dune crossing that is part of a beach access route and has a slope that exceeds 1:20 (5 percent) must also provide handrails that comply with section 505 of the ABA Standards and must...
-
Clear Width [§405.5]
Clear Width [§405.5] Ramp runs must have a clear width of 36” minimum (measured between handrails where provided)....
-
408.4.3 Platform to Hoistway Clearance
The platform to hoistway clearance shall comply with 407.4.3....
-
408.4.3 Platform to Hoistway Clearance
The platform to hoistway clearance shall comply with 407.4.3....
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. [2010 ADAS] Advisory 1003.3 Clearances. ...
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. [2010 ADAS] Advisory 1003.3 Clearances....
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. Advisory 11B-1003.3 Clearances....
-
4.32.3 Knee Clearances
If seating for people in wheelchairs is provided at tables or counters, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided (see...
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall...
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior...
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior...
-
1132A.5.2 Strike edge maneuvering space at doors
Twenty-four inches (610 mm) is preferred for strike edge clearance. ...
- McGuire Manufacturing Co., Inc. 1149WC: Offset with 149 Flat Grid Strainer
-
1132A.5.2 Strike edge maneuvering space at doors
Twenty-four inches (610 mm) is preferred for strike edge clearance....
-
1132A.5.2 Strike edge maneuvering space at doors
Twenty-four inches (610 mm) is preferred for strike edge clearance....
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
-
Knee and Toe Space Depth
[See subsections ...]
-
Clearance: ADA Standard Section 604.9.2
Section 604.9.2 covers the current ADA Standards for clearances around children's use water closets.