[DSA·AC & HCD 1-AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
Search Results "Exit Door"
-
1009.3 Stairways
-
1009.3 Stairways
[DSA·AC & HCD 1-AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
D. Clear Floor Space
If there is a vestibule without fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged door (i.e.: for out-swinging doors, at least 7'...
- Automatic sliding door systems Besam SL500
-
C. Clear Floor Space
When there is a vestibule into the public or employee restroom that does not have fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged...
-
Doorways [4.8.4]
Landings must provide the maneuvering clearance at doors required in ADAAG 4.13. ADAAG allows the landing to overlap maneuvering clearances at doors....
-
Can stair handrail extensions overlap door maneuvering clearances?
No, handrails and other elements cannot overlap door maneuvering clearances....
- CS SofStop Pocket Door Kit
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
11B-404.2.7 Door and gate hardware
Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
- Mockett DH2 Door Handle Installation
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
1007.6 Areas of refuge
is used as an area of refuge, the shaft and lobby shall comply with Section 1019.1.8 for smokeproof enclosures except where the elevators are in an area of refuge formed by a horizontal exit...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
6.3(1)
(1) Each bedroom shall have a door that complies with 4.13....
-
Doors [9.2.2(3), 9.4]
Doors [9.2.2(3), 9.4] Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible...
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
4.13.2 Revolving Doors and Turnstiles
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
4.13.2 REVOLVING DOORS AND TURNSTILES
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
Clear With [sic] [§404.2.3]
Clear With [sic] [§404.2.3] The clear width is measured from the stop to the face of doors or gates open 90⁰ (or to the leading edge of sliding or folding doors....