11B-606.2 Clear floor space....
Search Results "Centered Clear Floor Space"
-
11B-606.2 Clear floor space
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
R404.3 Size
Clear spaces shall be 760 mm (2.5 ft) minimum by 1220 mm (4.0 ft) minimum....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
1013.2 Clear Ground Space
This section requires a clear ground space 4 feet wide minimum to be provided on all usable sides of tent pads and tent platforms to enable individuals who use wheeled mobility devices to...
-
Bathroom Design Illustrations
However, the second set of specifications provides for a clear access aisle adjacent to the tub that would permit a parallel approach to the tub....
-
Outdoor Rinsing Showers [1011.2, 1011.3, and 1011.7]
At outdoor rinsing showers, a minimum of 60 by 60 inches of clear ground space must be provided....
-
M13
For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
Path-of-Travel (wheelchair) space allowances.xii In general, a 36” wide accessible route is needed with a slightly larger space provided at corners....
-
Clear Floor and Turning Space Inside Examination Rooms
The minimum amount of space required is 30 inches by 48 inches. Clear floor space is needed along at least one side of an adjustable height examination table....
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
Vending Machines and Other Equipment [5.8]
Vending Machines and Other Equipment [5.8] Since vending machines often are not fixed, ADAAG only requires that clear space be available at them for a forward or side approach and that...
- Access Board: Clear Floor Space Position
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...