R302.4 Passing Spaces. Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
Search Results "Centered Clear Floor Space"
-
R302.4 Passing Spaces
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
2. Accessible lavatory with knee and toe space
Accessible lavatory with knee and toe space below, faucet controls usable with a loosely closed fist, clear floor space for front approach, and lowered mirror....
-
R404.3 Size
Clear spaces shall be 760 mm (2.5 ft) minimum by 1220 mm (4.0 ft) minimum....
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
Outdoor Rinsing Showers [1011.2, 1011.3, and 1011.7]
At outdoor rinsing showers, a minimum of 60 by 60 inches of clear ground space must be provided....
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
- Access Board: Clear Floor Space Position
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
11B-606.2 Clear floor space
11B-606.2 Clear floor space....
-
Bathroom Design Illustrations
However, the second set of specifications provides for a clear access aisle adjacent to the tub that would permit a parallel approach to the tub....
-
1013.2 Clear Ground Space
This section requires a clear ground space 4 feet wide minimum to be provided on all usable sides of tent pads and tent platforms to enable individuals who use wheeled mobility devices to...
-
M13
For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
Path-of-Travel (wheelchair) space allowances.xii In general, a 36” wide accessible route is needed with a slightly larger space provided at corners....
-
Vending Machines and Other Equipment [5.8]
Vending Machines and Other Equipment [5.8] Since vending machines often are not fixed, ADAAG only requires that clear space be available at them for a forward or side approach and that...
- Landscape Forms Inc. Sort Recycling Units
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
Clear Floor and Turning Space Inside Examination Rooms
The minimum amount of space required is 30 inches by 48 inches. Clear floor space is needed along at least one side of an adjustable height examination table....
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....