Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
Search Results "Bus Ramp"
Commonly Searched Documents
- 
    
  
  11B-402.2 Components
  
 - 
    
  
  402.2 Components
  
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
 - 
    
  
  402.2 Components
  
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
 - 
    
  
  11B-402.2 Components
  
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
 - 
    
  
  T215 Communication Features
  
First, a large transit agency, while noting that its fixed route bus fleet was already equipped with automated announcement systems, nonetheless expressed concern about the cost of complying...
 - 
    
  
  11B-402.2 Components
  
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
 - 
    
  
  Accessible Routes [ยง402]
  
Accessible Routesย [ยง402] Components of accessible routes include walking surfaces, doorways, ramps, curb ramps, elevators, and, where permitted, platform lifts....
 - SafePath VulcanLandingโข Rubber Transition Ramp
 - 
    
  
  405.7.3 Length
  
The landing clear length shall be 60 inches (1525 mm) long minimum.
 - 
    
  
  11B-405.7.2.1
  
Top landings shall be 60 inches (1524 mm) wide minimum.
 - 
    
  
  405.7.3 Length
  
The landing clear length shall be 60 inches (1525 mm) long minimum.
 - 
    
  
  R407.6.3 Length
  
R407.6.3 Length. The landing clear length shall be 1.5 m (5.0 ft) long minimum.
 - 
    
  
  405.7.3 Length
  
405.7.3 Length. The landing clear length shall be 60 inches (1525 mm) long minimum.
 - 
    
  
  11B-405.7.3 Length
  
The landing clear length shall be 60 inches (1524 mm) long minimum.
 - 
    
  
  4.8.4(2)
  
(2) The landing length shall be a minimum of 60 in (1525 mm) clear.
 - 
    
  
  11B-405.7.2.1
  
Top landings shall be 60 inches (1524 mm) wide minimum.
 - 
    
  
  11B-405.7.3 Length
  
The landing clear length shall be 60 inches (1524 mm) long minimum.
 - 
    
  
  11B-405.7.3 Length
  
The landing clear length shall be 60 inches (1524 mm) long minimum.
 - 
    
  
  3. Are ramps, transfer systems, and stairs permitted to be counted as play components?
  
Are ramps, transfer systems, and stairs permitted to be counted as play components? No....
 - 
    
  
  DSA Drawing 11B-406-10C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  Detectable Warnings [4.7.7]
  
Since curb ramps remove this detectable drop-off, ADAAG originally required a distinctive dome patterning for the surface of curb ramps detectable by canes or by foot so that people with...
 - 
    
  
  1.1.15 Flatness of ramp landings
  
1.1.15 Flatness of ramp landings. Measure ramp landings at the midpoints of each landing in each direction using a 24 - in (600 mm) digital inclinometer....
 - 
    
  
  f-v
  
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided at every 30 feet of horizontal length?...
 - 
    
  
  ยง 38.125(c)(4) Ramp barriers
  
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....