The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
Search Results "Water Closet Grab Bar"
Commonly Searched Documents
-
11B-604.5.2 Rear wall
-
Location
When this grab bar was used (e.g....
-
Fittings: ADA Standard Section 609.6
Section 609.6 covers the current ADA Standards for the grab bar fittings.
-
4.22.4 Water Closets
4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging, self-closing door and parallel grab...
-
A4.16.4 Grab Bars
A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
A4.16.4 GRAB BARS
A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
Grab Bars: ADA Standard Section 607.4
Section 607.4 covers the current ADA Standards for bathtub grab bars.
-
Grab Bars: ADA Standard Section 608.3
Section 608.3 covers the current ADA Standards for grab bars in shower compartments.
-
GRAB BAR
[DSA-AC] A bar for the purpose of being grasped by the hand for support. Advisory Definition of GRAB BAR....
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609....
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609....
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609....
-
11B-609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with Section 11B-609....
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609....
-
11B-609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with Section 11B-609....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
11B-609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with Section 11B-609....
-
11B-604.5.1 Side wall
FIGURE 11B-604.5.1 ‡‡ SIDE WALL GRAB BAR AT WATER CLOSETS ETA Editor's Note At Hospital toilets and bathrooms used by patients, the 2013 California Electrical Code (2013 CEC)...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-213.3.2 Water closets