Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
Search Results "Side Reach"
Commonly Searched Documents
-
Side Entry: ADA Standard Section 1002.4.4.2
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
(a) Reach Depth Not More Than 10 in (255 mm)....
-
4.25.3 HEIGHT
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
4.25.3 Height
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6 (see Fig. 5 and Fig 6)....
-
General: ADA Standard Section 308.1
Section 308.1: of the ADA Standards covers information in the current ADA Standards for reach ranges.
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed....
-
4.34.3(2)(b) Reach Depth More Than 10 in
(b) Reach Depth More Than 10 in (255 mm)....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
- Figure 308.3.2 Obstructed High Side Reach – Drawing from the U.S. Access Board
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.1 General
Reach ranges shall comply with Section 11B-308. Advisory 11B-308.1 General....
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
Reach Ranges
Reach Ranges. The 1991 Standards set the maximum height for side reach at 54 inches above the floor....
-
3.5.3 Signs in General
If materials need to be obtained from or manipulated on a sign or kiosk, the sign or kiosk shall be designed to meet the reach ranges in section 308 of the ABAAS....
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
4.27.3* Height
The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
A4.27.3 Height
Electrical receptacles installed to serve individual appliances and not intended for regular or frequent use by building occupants are not required to be mounted within the specified reach...
-
11B-308 Reach ranges
[See subsections ...]
-
11B-308.2 Forward reach
[See subsections ...]
-
A4.27.3 HEIGHT
Fig. A6 further illustrates mandatory and advisory control mounting height provision for typical equipment. Note distinction between built-in equipment (considered real property) and...
-
2. c. REACH RANGES
The maximum reach ranges (detailed below) should be considered in the placement of information brochures, magazines and other items located in medical office lobbies, reception, and waiting...
-
4.31.3* Mounting Height
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6....
-
4.34.3(3) Forward and Parallel Approach
If both a forward and parallel approach are possible, operable parts of controls shall be placed within at least one of the reach ranges in paragraphs (1) or (2) of this section....