(a) New facilities—
Search Results "Rest Stop"
-
§27.75(a) New facilities.
-
10.2.2(1)
(1) Bus stop sites shall be chosen such that, to the maximum extent practicable, the areas where lifts or ramps are to be deployed comply with section 10.2.1(1) and (2)....
-
7.4.4.1 Length
The resting interval length shall be 60 inches (1525 mm) long minimum....
-
F209.2.3 On-Street Bus Stops
On-street bus stops shall comply with 810.2 to the maximum extent practicable....
-
209.2.3 On-Street Bus Stops
On-street bus stops shall comply with 810.2 to the maximum extent practicable....
-
7.4.4.3 Slope
The slope of a resting interval shall not exceed 1:20 (5 percent) in any direction....
-
Bus Boarding and Alighting Areas: ADA Standard Section 810.2
At bus stops where a shelter is provided, the bus stop pad can be located either within or outside of the shelter....
-
11B-810.2 Bus boarding and alighting areas
At bus stops where a shelter is provided, the bus stop pad can be located either within or outside of the shelter. ◼...
-
11B-810.2 Bus boarding and alighting areas
At bus stops where a shelter is provided, the bus stop pad can be located either within or outside of the shelter. ◼...
-
11B-209.2.3 On-street bus stops
On-street bus stops shall comply with Section 11B-810.2 to the maximum extent practicable....
-
11B-209.2.3 On-street bus stops
On-street bus stops shall comply with Section 11B-810.2 to the maximum extent practicable....
-
11B-209.2.3 On-street bus stops
On-street bus stops shall comply with Section 11B-810.2 to the maximum extent practicable....
-
T215.3.2 Stop Request Systems
Where non-rail vehicles stop on passenger request, stop request systems complying with T704.3 shall be provided....
-
209 Passenger Loading Zones and Bus Stops
209 Passenger Loading Zones and Bus Stops...
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
2.5.4 Slope
Resting intervals shall not be steeper than 1:33 (3 percent) in any direction....
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-209 Passenger drop-off and loading zones and bus stops
209 Passenger Loading Zones and Bus Stops ETA Editor’s Note The CBC includes passenger drop-off. Therefore, the CBC is more inclusive....
-
10.2.1 New Construction
[See subsections ...]