This video is part of a longer animation produced by the U.S. Access Board. View the animation video in its entirety on the Access Board's website...
Search Results "Obstruction"
Commonly Searched Documents
- Access Board: Obstructed Forward Reach
-
4.3 Reach Ranges
Reaching over an obstruction was studied in the BS8300 study, and, the limits of obstructed reach can be derived from the IDEA data....
-
Question 1
YES/NO 1. Are all accessible parking spaces, access aisles, curb ramps, and connecting accessible routes clear of obstacles including vehicles without...
-
22.1 Q. Must the switches on range hood kitchen ventilation fans be in accessible locations?
A. No. Kitchen ventilation fans located on a range hood are considered to be part of the appliance. The Fair Housing Act has no requirements for appliances in the interiors of...
-
K5
K5. If the operating controls are set back 10 to 24 inches from the front edge of the counter or table are they no higher than 46 inches above the floor? [ADA Standards §...
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The Committee recommends a 3-inch maximum obstruction permitted at transfer sides....
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for...
-
4.34.3(2)(b) Reach Depth More Than 10 in
(b) Reach Depth More Than 10 in (255 mm). Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed...
-
A4.27.3 HEIGHT
Fig. A6 further illustrates mandatory and advisory control mounting height provision for typical equipment. Note distinction between built-in equipment (considered real property) and...
-
Question 15
YES/NO 15. Is the full length (minimum 3 feet) of the lowered counters of the accessible checkout aisles and sales counters clear of merchandise and...
-
Guidelines for Requirement 5
The final Guidelines clarify that to be in an accessible location within the meaning of the Act, the maximum height for an environmental control, for which reach is over an obstruction,...
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view the information shown in Fig. 4, 5, and...
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view information shown in Fig. 4, 5, and 6 in other...
-
A4.27.3 Height
Fig. A8 further illustrates mandatory and advisory control mounting height provisions for typical equipment. Electrical receptacles installed to serve individual...
-
3.5.3 Signs in General
If materials need to be obtained from or manipulated on a sign or kiosk, the sign or kiosk shall be designed to meet the reach ranges in section 308 of the ABAAS.
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over...
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over...
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
d. Unobstructed Transfer
The MDE NPRM proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they could be repositioned...
-
Reach Ranges
Section 308.3.1, Exception 1, permits an obstruction that is no deeper than 10 inches between the edge of the clear floor or ground space and the element that the individual with a disability...
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
Appendix 3 - Comparison of US Standards to IDEA Center Research
Low Side Reach 380 89 602 792 485 High Side Reach with Obstruction...