Section 609.5 covers the current ADA Standards for the surfaces of grab bars and adjacent surfaces.
Search Results "Grab Bar Clearance"
-
Surface Hazards: ADA Standard Section 609.5
-
1607A.9.2 Grab bars, shower seats and accessible benches
[DSA-AC & HCD 1-AC] See Chapter 11A, Section 1127A.4, and Chapter 11B, Sections 11B-609.8, 11B-610.4 and 11B-903.6, for grab bars, shower seats and dressing room bench seats, as applicable...
-
1009.4.5 Grab Bars
1009.4.5 Grab Bars. At least one grab bar complying with 609 shall be provided on the transfer wall....
-
1009.4.5 Grab Bars
Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
Grab Bars [4.16.4]
Grab Bars [4.16.4] The back grab bar is most usable from the open side. It must be 36 inches long minimum, installed with one end space a maximum of 6 inches from the side wall....
-
604.8.1.5 Grab Bars
604.8.1.5 Grab Bars. Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
- 604.5.2 Rear Wall Grab Bar Location
-
604.5 Grab Bars
Grab bars for water closets shall comply with 609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
604.8.1.5 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
604.8.1.5 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
Structural Strength: ADA Standard Section 609.8
Section 609.8 covers the current ADA Standards for the structural strength of grab bars.
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
4.16.4* Grab Bars
Grab bars for water closets not located in stalls shall comply with 4.26 and Fig. 29. The grab bar behind the water closet shall be 36 in (915 mm) minimum....
-
11B-609.9 Alternate configuration
L-shaped or U-shaped grab bars shall be permitted....
-
11B-609.9 Alternate configuration
L-shaped or U-shaped grab bars shall be permitted....
-
Grab Bars
Grab Bars A grab bar must be provided on at least one side of each step and on the transfer platform (shown on page 16), or as a continuous grab bar serving each step and the platform...
-
11B-1009.4.5 Grab bars
Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
Grab Bars
Specifications for grab bars are addressed in section 604.5. Grab bars are required on one side wall and the rear wall....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....