Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
Search Results "Exit Enclosure"
Commonly Searched Documents
-
11B-704.2.1.2 Forward approach
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
Exit Discharge [IBC §1023 (2003), §1006 (2000)]
Exit Discharge Steep terrain and other constraints can make it difficult to provide an accessible means of egress from building exits to a public way....
- BEA Inc. Product Line: ACPB Access Control Push Button (Push to Exit)
-
7. Seat Transfer
7. Are the roll-in showers free of doors that would impede wheelchair transfer onto the seat? [ADA Stds. 4.21.8] Yes __ No __ N/A __ Comments:...
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4....
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
- Young Equipment Sales Vinyl Bleacher End Closures
-
1003.2.13.2 Enclosed exit stairways
Section 1003.2.13.2 Change to read as shown: (E20-00) 1003.2.13.2 Enclosed exit stairways. ...
-
1007.3 Enclosed exit stairways
Exceptions: Open exit stairways as permitted by Section 1019.1 are permitted to be considered part of an accessible means of egress....
- SetonGlo™ ADA Braille Signs - Exit Route
-
1134A.5, Item 5
Bathtub enclosures. Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....