Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. §703.2 Raised Characters....
Search Results "Exit Enclosure"
-
ETA Opinion: ADA Signage at Exit Doors
-
1003.2.13.1 General.
Stairways within exit enclosures complying with Sections 1003.2.13.2 and 1005.3.2. Elevators complying with Section 1003.2.13.3....
-
1007.2 Continuity and components
Stairways within exit enclosures complying with Sections 1007.3 and 1019.1. Elevators complying with Section 1007.4....
-
4.3.11.1(4)
(4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required for corridors and openings....
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...
-
4.3.11.1(6)
The area or room shall be provided with an exit directly to an exit enclosure....
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC specifies maximum travel distances to reach an exit....
-
Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
The IBC contains requirements for exit stairway enclosures that address fire-resistance and smoke protection, stairways and handrails, signs, and other features....
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
They must provide direct access to an exit stairway (or to an elevator equipped with standby power). Horizontal exits can substitute for areas of refuge....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...
-
1013.4, Item 3
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
- Access Board: Exit Signs