At most elements, clear floor space can be positioned for either a forward approach or a side approach....
Search Results "Approach Enter Exit"
Commonly Searched Documents
-
Forward and Side Approaches
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. Clear floor or ground space may overlap...
-
1003.2.13.2 Enclosed exit stairways
Section 1003.2.13.2 Change to read as shown: (E20-00) 1003.2.13.2 Enclosed exit stairways. ...
-
1007.3 Enclosed exit stairways
Exceptions: Open exit stairways as permitted by Section 1019.1 are permitted to be considered part of an accessible means of egress....
-
Registered Accessibility Specialist (RAS) Bulletin RAS 2014-04 Signs - Exit Doors
RAS 2014-04 Signs - Exit Doors Effective Date: July 7, 2014 2012 TAS Reference: 216.4.1 In accordance with TAS 216.4.1, doors at exit passageways, exit discharges, and exit...
-
1009.3.2 Stairway width
The clear width of 48 inches (1219 mm) between handrails is not required for stairways accessed from a refuge area in conjunction with a horizontal exit....
-
Are exit doors usable only in one direction required to comply on both sides?
Under the ADA Standards, compliance is not required on both sides of those doors or gates that can be used in one direction only, such as exit-only doors....
- SetonGlo™ ADA Braille Signs - Exit Route
-
4.2.4.1 Size and Approach
The minimum clear floor or ground space for wheelchairs may be positioned for forward or parallel approach to an object (see Fig. 4(b) and (c))....
-
4.2.4.1 SIZE AND APPROACH
The minimum clear floor or ground space for wheelchairs may be positioned for forward or parallel approach to an object (see Fig. 4(b) and (c))....
- BEA Inc. Pneumatic Push Button Automatic Door Access (Push to Exit)
- BEA Inc. Piezo Push Button Heavy Duty Door Actuator (Push to Exit)
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1013.4, Item 3
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
704.2.1.1 Parallel Approach
704.2.1.1 Parallel Approach....
-
704.2.1.2 Forward Approach
704.2.1.2 Forward Approach....
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....