As we rebuild homes, community spaces and nonprofit facilities, our lasting impact helps to stabilize and revitalize neighborhoods across the country....
Search Results "Centered Clear Floor Space"
Commonly Searched Documents
- Rebuilding Together Central Ohio - Grove City, OH
-
3.13 General Requirements for all Modified Theaters
Unless otherwise provided herein, all modifications to the wheelchair spaces in Cinemark's Modified Theaters, described in paragraph 3.1-3.11 above, must comply with the following:...
-
11B-208.2.3.1 Parking for Residents
Parking for Residents Amends section to provide explicit requirements for the provision of accessible parking in situations where there is less than one parking space...
-
11B-502.8 Additional signage
shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space...
-
Adaptability
The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of individuals with or without...
-
Trailhead
For purposes of the FSORAG and FSTAG, a trailhead is an outdoor space that is designated by an entity responsible for maintaining or administering the trail to serve as an access point to...
-
Elongated surface openings must be perpendicular to the dominant direction of travel, but what if there is no dominant direction of travel?
Where space allows accessible routes to completely bypass the area with openings, elongated openings can be oriented in either direction....
-
Elevator Car Requirements [§407.4]
Alternative configurations that provide unobstructed wheelchair turning space (60” diameter circle or T-turn) with the doors closed are permitted....
-
§ 38.107(b)
(b) Restrooms required to be accessible shall be in close proximity to at least one seating location for persons using mobility aids and shall be connected to such a space by an unobstructed...
-
11B-502.8 Additional signs
shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space...
-
ASSISTIVE LISTENING SYSTEM (ALS)
[DSA-AC] An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop,...
-
11B-502.8 Additional signs
shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space...
-
ASSISTIVE LISTENING SYSTEM (ALS)
[DSA-AC] An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop,...
-
2.2.3 Functional Reach
reach envelope required that the reach envelope be measured relative to certain environmental, wheelchair and personal features (e.g. 3-D envelopes measured relative to a point on the floor...
-
Problem Four (Accessible Route)
Or, if a church basement located down a flight of stairs is used as the voting area, perhaps one of the ground floor rooms could be used as the voting area....
-
1007.8 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
1003.2.13.7 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
Protruding Objects [4.4]
The standard sweep of canes allows detection of objects with leading edges up to 27 inches from the floor....
-
Scoping [4.1.3(8)]
number of public entrances (whichever is greater); and at least one entrance to each separate tenancy is accessible at least one accessible entrance serves the ground floor...
-
4.21.3 Seat
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall....
-
4.10.14* EMERGENCY COMMUNICATIONS
The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....